The Caleffi iStop® 108602 frost protection valve, G1" (DN25), protects heat pumps against freezing in the event of a power failure – it operates purely mechanically, without electronics. It opens at 3 °C and closes at 4 °C. Pressure up to 10 bar. More information
Delivery to Belgium (days are avarages)
DHL Express: 1.1 workdays, € 16,94
| Connection size | 1" |
| Connection Type | External thread |
| Pressure | 10 bar |
| Temperature | 0...90 °C |
| Weight | 0.35 kg |
Caleffi iStop® 108602 frost protection valve, G1" DN25 (108602) is a mechanical valve that protects heat pumps against frost damage in the event of a power failure. The valve responds to a drop in the temperature of the flowing medium and, without the need for electricity or electronics, drains the endangered water from the system before ice can form.
The valve is installed on heat pumps, especially outdoor monobloc units, where there is a risk of the heat exchanger freezing during a power outage without a backup power source. For reliable protection, 2 valves are always installed – one on the flow pipe and one on the return pipe, as close to the pump as possible, because it cannot be determined in advance which branch will cool down more quickly.

Autonomous protection
Power consumption
0 W
Purely mechanical principle, operates even during a power outage
iStop®
Patent status
Patent pending
Unique iStop® mechanism design
No calibration
Opening / closing temperature
3 °C / 4 °C
Installation without adjustment or calibration
Technical parameters:
For reliable heat pump protection, 2 valves must be installed – one on the flow pipe and one on the return pipe, as close to the pump as possible. This is because it cannot be determined with certainty in advance which branch of the system will cool down more quickly, as this is influenced by a number of factors including ambient conditions.
No. The valve contains a thermostatic sensor that must respond to the actual temperature of the medium. If it were insulated, water in another, less insulated part of the system (for example in the pump heat exchanger) could freeze before the valve has time to respond.
Not always – the valve works correctly even without it. However, in non-standard configurations, for example with some plate heat exchangers, an automatic filling valve helps maintain water circulation throughout the entire heat exchanger and protects the pump even during a prolonged power outage.
Yes. The valve is full-bore and generates very low pressure loss, so even when connected via a reducer to pipework of a different diameter, the increase in pressure loss in the system remains negligible.
Freezing occurs if the electrical power supply fails and the household does not have a backup power source (for example a generator). A monobloc heat pump without frost protection can then freeze at low temperatures – under normal power supply it can cope with the cold on its own.
We respond to your product queries as quickly as possible, usually within 24 hours.