Chlorine detector Evikon E2608-CL2, two relays with switch-over contact, RS485 Modbus RTU digital interface and two analog outputs settable to 4-20 mA or 0-10 V. Industrial IP65 housing. Power supply 230V. More information
Out of stock - can be requested
Would you like to get a price offer? Contact us
Detector type | To VZT cannal |
Output signal | ModBus RS485, 2x Switching relay, 2x Analog output 4-20mA/0-10V |
Power | 24 VDC, 230 VAC |
Type of gas | CL2 - Chlorine |
Weight | 0.35 kg |
Declaration of Conformity download
Download PDFDatasheet download
Download PDFChlorine detector is used to detect and warn of dangerous (toxic) concentrations in a timely manner. The E2608-CL2 detectors are designed to detect hazardous chlorine concentrations in swimming pools and spas, wastewarer treatment plants and other confined spaces, where potentially toxic concentration of chlorine can accumulate. The DM design allows the detector to be installed directly into the duct.
Chlorine is heavier than air. Therefore, chlorine detectors should be mounted approximately 15cm above the floor. When used in air ducts it is placed directly at the flow point.
The EVIKON E2608-CL2 detector is equipped with two-stage signaling with outputs to the switching relay. It does not have its own visual and acoustic signaling. The E2608 series detectors are an intelligent solution for modern applications with ModBus RS485 communication and two 4-20mA/0-10V analog outputs.
Made in robust design with IP65 protection - ABS plastic, resistant to mechanical damage. Rigid, tough, resistant to low and high temperatures, poorly absorbent, harmless to health. The service life of the detector is more than 10 years.
Each detector is factory calibrated to the default values (described in the manual). The law states that recalibration must be performed at least once every 12 months. Calibration may only be performed by a person certified by the manufacturer.
The detector is designed to detect chlorine:
CL2
Tip: Get notified by the service about the date of legal calibration www.kalibrovat.cz
We respond to your product queries as quickly as possible, usually within 24 hours.
Shopping with us
Personal collection of goods
Opening hours
Payment options
Delivery options
Contact
Copyright © 2024 BOLA spol s.r.o.
Didn't find what you wanted to know?