Coolant detector EVIKON E2610-HFC-230-NC (R32) for heat pumps

  • 2 variants

Coolant detector EVIKON E2610-HFC-230-NC (R32) for heat pumps

EVIKON
  • Product code: E2610-HFC-230-NC
  • Manufacturer code: E2610-HFC-230-NC
  • Warranty: 2 years

EVIKON E2610-HFC refrigerant gas detector, warning signal: light LED + sound, measurement range: 0...500 ppm R32. More information

  • Availability

    GLS delivery 3-4 working days. DHL express delivery 1-2 working days.

  • In stock 3 pcs  
     
Price without VAT € 188,60
Price with VAT 21 % € 228,21

Varianty produktu

+

Would you like to get a price offer? Contact us

Parameters and catalogs

Detector type Stationary
Output signal Switching relay
Power 230 VAC
Type of gas HFC-Coolants - R32
Weight 0.35 kg

CATALOG SHEET ENG download

Download PDF

R32 Flammable Refrigerant Leak Detector for Evikon E2610-HFC-NC Heat Pumps

The gas concentration detection sensor (gas detector) is used for detection and early warning of a dangerous (explosive) concentration of the sensed refrigerant. The sensor is suitable for detecting refrigerant leaks from cooling devices, air conditioners and heat pumps.

The sensor is equipped with two-stage signaling - visual (LED) and sound (85db) . Two output relays with changeover contact can be used for remote signaling or ventilation control. The set switching points are: Relay1= 200ppm , Relay2= 500ppm .

Initial calibration

A temperature-compensated, durable semiconductor sensor is used for sensing. The service life of the sensor is more than 5 years. The sensor is non-selective = calibrated to R32 -> responds to other refrigerants (R-12, R-123, R-125, R-134a, R-143, R-22, R-404a, R-407c, R-410a, R1234yf and others), flammable gases, vapors from solvents and cleaning agents. The recommended coverage area with one sensor is 80-120 m 2 , 5-6 m radius .

Each sensor is factory calibrated and the calibration protocol in AJ is included in the package.

Test button

The detector is equipped with a test button that starts self-diagnostics of the sensor. Diagnostics checks the electrical response of the sensor and after 64 seconds the device measures stably again. Diagnostics does not turn on the relay.

Properties:

  • Sensitive and stable detection of refrigerants
  • Long service life of the semiconductor sensor
  • Wall mounting, protection IP20
  • Visual and audible alarm
  • Two output relays for alarm / ventilation control

Tip: Let the www.kalibrovat.cz service automatically notify you of the legal calibration date