Privacy settings on bolasystems.com
Necessary cookies: Necessary for the proper functioning of the website. These cannot be deactivated.
Analytical cookies: They help us understand how you use our website, allowing us to improve it. This includes Google Analytics.
Marketing cookies: They are used to track visitors across websites to display relevant advertisements. This includes Google Ads and Google Enhanced Conversions technology.
Carbon Monoxide Detector Evikon E2670-NH3 with digital ModBus RS485 communication and two analogue outputs 4-20mA/0-10V and two relays. IP66 protection. Power supply 24 VDC. Suitable for ATEX zones 2 and 22. More information
Out of stock - can be requested
| Atex | Zone 22, Zone 2 |
| Output signal | ModBus RS485, 2x Analog Output 4-20mA/0-10V |
| Power Supply | 24 VDC |
| Type of gas | NH3 - Ammonia |
| Weight | 1.00 kg |
Data sheet eng download
Download PDFDeclaration of staircase download
Download PDFCarbon Monoxide Detector is used to measure the values of detected gas in the air and provide timely warning of dangerous (toxic) concentrations. Solvent fumes can explode at high concentrations. Therefore, it is necessary to ensure timely leak warnings using the detector.
It does not have its own light and sound signaling. The E2670 series detectors are an intelligent solution for modern applications with ModBus RS485 communication and two analog outputs 4-20mA/0-10V. They are also equipped with two switching relays that activate connected devices upon recording two preset values.
Manufactured in a robust aluminum design with IP66 protection, resistant to mechanical damage. Rigid, tough, resistant to low and high temperatures, non-hazardous to health. Suitable for use in ATEX zones 2 and 22. More details on ATEX in the declaration of conformity and data sheet.
Each detector is factory-calibrated to default values (described in the manual). According to user needs, the detector can be set to a toxicity range of 0...300 ppm. The law states that recalibration must be performed at least once every 6 months. Calibration can only be performed by a person certified by the manufacturer.
The recommended coverage area for one sensor is 80-120 m2, 5-6 m radius.
For recalibration, do not hesitate to contact us!
Tip: Get automatically notified of the legal calibration date with the service www.kalibrovat.cz