Gas Detector for Flammable Gases EVIKON E2638-R-LPG-LCD, warning signal: visual (flashing display) + audible, LCD display with current measured value, power supply: 90...265 VAC, measurement range: 0-100%LEL. More information
Out of stock - can be requested
| Detector type | Stationary |
| Output signal | ModBus RS485, 2x Switching Relay, 2x Analog Output 4-20mA/0-10V |
| Power Supply | 230 VAC |
| Type of gas | LPG-Propane-Butane, CH4-Methane, H2-Hydrogen, C4H10-Butane, C3H8-Propane, C2H2-Acetylene |
| Weight | 0.50 kg |
Declaration of conformity download
Download PDFThe gas concentration detection sensor (gas detector) is designed to detect and provide early warning of dangerous (explosive or toxic) concentrations of the monitored gas. The sensor is suitable for use in underground garages, boiler rooms, kitchens, and other enclosed spaces where dangerous amounts of gas may accumulate. The detector is equipped with a two-stage alarm system – visual (LCD display) and audible (85db). Additionally, two output relays (voltage-free) with a switching contact can be used for remote signaling or control of ventilation/EM valve, etc. The sensor is built on the unified PluraSens platform. The platform allows the detector to connect, besides switching relays, also with two analog outputs 0-10V / 4-20mA and a digital ModBus RS485 interface.
Manufactured in a robust design with IP65 protection - ABS plastic, resistant to mechanical damage. Rigid, tough, resistant to low and high temperatures, low absorbency, non-toxic.
The sensor's lifespan is more than 10 years.
The default alarm values are set at 10% and 20% of the lower explosive limit of propane (LEL). The detector also responds to other flammable gases. The recommended coverage area for one sensor is 80-120 m2, 5-6m radius.
Each sensor is factory-calibrated to default values (10 and 20% LEL). The law states that recalibration must be performed at least once every 12 months. Calibration can only be performed by a person certified by the manufacturer.
For more information on calibrations - www.kalibrovat.cz
The sensor is intended for the detection of flammable gases:
Methane (CH4), Propane (C3H8), Butane (C4H10), Hydrogen (H), Acetylene (C2H2)
DETECTOR CALIBRATED FOR PROPANE.
Tip: Get automatically notified of the statutory calibration date with the service www.kalibrovat.cz
Tip: The detector can be equipped with a remote wired sensor.
We respond to your product queries as quickly as possible, usually within 24 hours.