Ozone detector EVIKON E2608-O3-230

Ozone detector EVIKON E2608-O3-230

EVIKON
  • Product code: E2608-O3
  • Manufacturer code: E2608-O3
  • Warranty: 2 years

Ozone detector Evikon E2608-LEL with two relays with switch-over contact, RS485 Modbus RTU digital interface and two analog outputs settable to 4-20 mA or 0-10 V. Industrial IP65 housing. Power supply 230V. More information

  • Availability

    Out of stock - can be requested

  • Out of stock  
Price without VAT € 711,97
Price with VAT 21 % € 861,48
+

Would you like to get a price offer? Contact us

Parameters and catalogs

Detector type To VZT cannal
Output signal ModBus RS485, 2x Switching relay, 2x Analog output 4-20mA/0-10V
Power 24 VDC, 230 VAC
Type of gas O3 - Ozone
Weight 0.44 kg

Declaration of Conformity download

Download PDF

Datasheet download

Download PDF

Ozone detector is used for the detection and early warning of dangerous (toxic) concentrations. The DM design allows the detector to be installed directly into the duct.

Ozone drops to the floor. Therefore, ozone detectors should be installed above the floor. When used in air ducts it is placed directly at the flow point.

The EVIKON E2608-O3 detector is equipped with two-stage signaling with outputs to the switching relay. It does not have its own visual and acoustic signaling. The E2608 series detectors are an intelligent solution for modern applications with ModBus RS485 communication and two 4-20mA/0-10V analog outputs.

The detector can be ordered in the following versions:

    • wall-mount (in stock)
    • duct-mount (on request)
    • with cable probe (on request)

    Made in robust design with IP65 protection - ABS plastic, resistant to mechanical damage. Rigid, tough, resistant to low and high temperatures, poorly absorbent, harmless to health. The service life of the detector is more than 10 years.

    Each detector is factory calibrated to the default values (described in the manual). The law states that recalibration must be performed at least once every 12 months. Calibration may only be performed by a person certified by the manufacturer.

    Do not hesitate to contact us for recalibration!

    The detector is designed to detect ozone:

    O3

    Features:

    • Selective, sensitive and stable detection
    • Long-life electrochemical sensor
    • Wall, duct mounting, remote probe, IP65 protection
    • Two relays for alarm/ventilation control
    • Two analog outputs settable to 4-20 mA or 0-10 V
    • RS485 Modbus RTU digital interface

    Tip: Get notified by the service about the date of legal calibration www.kalibrovat.cz