Refrigerants detector EVIKON E2611-W-HFC-230 with two switching relays, digital communication ModBus RS485 and two analog outputs 4-20mA/0-10V. Protection class IP65. Power supply 230V. More information
GLS delivery 3-4 working days. DHL express delivery 1-2 working days.
Would you like to get a price offer? Contact us
Detector type | Stationary |
Output signal | ModBus RS485, 2x Switching relay, 2x Analog output 4-20mA/0-10V |
Power | 230 VAC |
Type of gas | HFC-Refrigerants |
Weight | 0.35 kg |
Datasheet download
Download PDFDECLARATION OF CONFORMITY download
Download PDFRefrigerants detector is used to detect and warn early of a dangerous (toxic) concentration of the refrigerant being sensed. It is important to detect leakage of previously used chlorofluorocarbons (CFCs) and of today's HFCs. The leakage of these gases has a negative impact on the environment and the formation of the ozone layer. In the event of leakage, refrigerant may also accumulate in enclosed spaces up to toxic levels. It is therefore necessary to provide early warning of leakage using a detector.
Hydrocarbon refrigerants tend to decline because they are heavier than air. Refrigerant detectors should therefore be mounted to the floor near a potential leak location. The recommended coverage area of one detector is 80 ... 120m2, which corresponds to a radius of about 5 ... 6m.
Refrigerant detectors have a wide range of use, ranging from cold storage warehouses, skating arenas, and other areas, where leakages of halocarbon refrigerants are possible.
The EVIKON E2611-W-HFC detector is equipped with two-stage signaling with outputs to the switching relay. It does not have its own visual and acoustic signaling. The E2608 series detectors are an intelligent solution for modern applications with ModBus RS485 communication and two 4-20mA/0-10V analog outputs.
Made of white ABS plastic, resistant to mechanical damage. The service life of the detector is more than 10 years.
Each detector is factory calibrated to the default values (described in the manual). The law states that recalibration must be performed at least once every 12 months. Calibration may only be performed by a person certified by the manufacturer.
The detector is designed to detect refrigerants:
R-12, R-123, R-125, R-134a, R-143, R-22, R-404a, R-407c, R-410a, etc.
The detector is factory calibrated with R-404a.
Tip: Get notified by the service about the date of legal calibration www.kalibrovat.cz
We respond to your product queries as quickly as possible, usually within 24 hours.
Didn't find what you wanted to know?