Room temperature controller for two-pipe fan coil units. Exhaust air sensor input. More information

  • Delivery

    Delivery to Belgium (days are avarages)

    GLS:
    3.2 workdays € 8,99
    Bpost HD (Home Delivery):
    2.8 workdays € 10,56
    BPost - PP (Pick-up Point):
    3 workdays € 10,01
    PostNL BE HD (Home Delivery) :
    4.1 workdays € 10,08
    DHL Economy:
    2.5 workdays € 20,96
    DHL Express:
    1.5 workdays € 30,86

    GLS: 3.2 workdays, € 8,99

  • More than 5 pcs in stock  
     
List price € 94,14
Price without VAT € 62,24
Price with VAT 21 % € 75,31
+

Would you like to get a price offer? Contact us

Parameters and catalogs

Control Control wheel
Design Wired
External sensor Yes
Measurement accuracy 0,7 °C
Power 230 VAC
Programme No
Regulation Three-stage
Setting range 8...30 °C
Weight 0.25 kg

Datasheet download

Download PDF

Room temperature controller RCC 10 for two-pipe fan coil units with electric heating. The regulator
is equipped with a knob for setting the desired temperature, a switch and status LEDs.

Usage

Room temperature control in rooms heated or cooled by two-pipe fan coil units.Two-position valve control and 3-turn fan control.

The regulator is suitable for use in systems with automatic heating/cooling sequence switching and in systems with continuous operation in heating or cooling sequence.

Function

By means of the built-in temperature sensor or via an additional temperature sensor (QAH 11.1), the regulator
acquires the current temperature information and ensures the temperature control to the setpoint. The control takes place via 2-position control of the regulator valve actuator (open/closed).

Operating modes

Normal operation - heating or cooling sequence with automatic changeover and manually set fan speed III, II or I. In this mode, the controller reacts to the set temperature setpoint.

Frost protection mode - when the temperature drops below 8 °C, the controller opens the heating valve and the fan runs at the set speed.

Power saving mode - the value of heating in power saving mode is 16 °C and the value for cooling is 28 °C.

Protection against increased humidity