Gas detector for hydrogen EVIKON E2670-LEL(H2)-R-230

Gas detector for hydrogen EVIKON E2670-LEL(H2)-R-230

EVIKON
  • Product code: E2670-LEL(H2)-R-230
  • Manufacturer code: E2670-LEL(H2)-R-230
  • Warranty: 2 years

Evikon E2670-R-LEL hydrogen detector with ModBus RS485 digital communication and two analog outputs 4-20mA/0-10V and two relays. Protection IP66. Power supply 230V AC. Suitable for ATEX zones 2 and 22. More information

  • Availability

    Out of stock - can be requested

  • Out of stock  
Price without VAT € 681,56
Price with VAT 21 % € 824,69
+

Would you like to get a price offer? Contact us

Parameters and catalogs

Atex Zone 22, Zone 2
Output signal ModBus RS485, 2x Analog output 4-20mA/0-10V, 2 x switching relays
Power 230 VAC
Type of gas CH4-Methane, H2-Hydrogen, C4H10-Butane, C3H8-Propane, C2H2-Acetylene, H2-Hydrogen
Weight 1.00 kg

DATA SHEET ENG download

Download PDF

DECLARATION OF STAIRCASE download

Download PDF

The hydrogen detector is used to measure the values ​​of the detected gas in the air and provide early warning of a dangerous (toxic) concentration.

It does not have its own light and sound signaling. The E2670 series detectors are an intelligent solution for modern applications with ModBus RS485 communication and two 4-20mA/0-10V analog outputs . They are also equipped with two switching relays that will switch the connected devices after recording two preset values.

Made in a robust aluminum design with IP66 protection , resistant to mechanical damage. Rigid, tough, resistant to low and high temperatures, harmless to health. Suitable for use in ATEX zones 2 and 22 . More details about ATEX in the Declaration of Conformity and Technical Data Sheet.

Each detector is factory-calibrated to default values ​​(described in the manual). According to the needs of the user, the detector can be set to a measuring range of 0...100% LEL. The law states that recalibration must be carried out at least once every 12 months. Calibration can only be performed by a person certified by the manufacturer.

The recommended coverage area with one sensor is 80-120 m 2 , 5-6 m radius.

Do not hesitate to contact us for recalibration!

The detector is designed to detect:
Acetylene / Butane / Propane / Hydrogen / Methane
Factory calibrated to Hydrogen (To set to a different gas, provide information in the order note)

Properties:

  • Sensitive and stable detection
  • Long service life of the semiconductor sensor
  • Wall mounting, IP66 protection
  • ATEX zones 2, 22
  • Two analog outputs 4-20mA/0-10V
  • ModBus RS485 digital communication
  • 2 x switching relays