Gas Detector for Hydrogen EVIKON E2670-LEL(H2)-R-230

Gas Detector for Hydrogen EVIKON E2670-LEL(H2)-R-230

EVIKON
  • Product code: E2670-LEL(H2)-R-230
  • Manufacturer code: E2670-LEL(H2)-R-230
  • Warranty: 2 years

Hydrogen Detector Evikon E2670-R-LEL with digital ModBus RS485 communication and two analog outputs 4-20mA/0-10V and two relays. IP66 protection. Power supply 230V AC. Suitable for ATEX zones 2 and 22. More information

  • Availability

    Out of stock - can be requested

  • Out of stock  
Price excluding VAT € 716,00
Price with VAT 21 % € 866,36
+

Parameters and catalogs

Atex Zone 22, Zone 2
Output signal ModBus RS485, 2x Analog Output 4-20mA/0-10V, 2 x switching relay
Power Supply 230 VAC
Type of gas CH4-Methane, H2-Hydrogen, C4H10-Butane, C3H8-Propane, C2H2-Acetylene, H2-Hydrogen
Weight 1.00 kg

Data sheet eng download

Download PDF

Declaration of staircase download

Download PDF

Hydrogen Detector is used for measuring the values of detected gas in the air and providing timely warnings against dangerous (toxic) concentrations.

It does not have its own light and sound signaling. The E2670 series detectors are an intelligent solution for modern applications with ModBus RS485 communication and two analog outputs 4-20mA/0-10V. They are also equipped with two switching relays that activate connected devices upon recording two pre-set values.

Manufactured in a robust aluminum design with IP66 protection, resistant to mechanical damage. Rigid, tough, resistant to both low and high temperatures, non-hazardous to health. Suitable for use in ATEX zones 2 and 22. More details on ATEX can be found in the declaration of conformity and technical sheet.

Each detector is factory-calibrated to default values (described in the manual). According to user needs, the detector can be set to a measuring range of 0...100% LEL. The law states that recalibration must be performed at least once every 12 months. Calibration can only be performed by a person certified by the manufacturer.

The recommended coverage area for one sensor is 80-120 m2, 5-6 m radius.

For recalibration, do not hesitate to contact us!

The detector is designed to detect:
Acetylene / Butane / Propane / Hydrogen / Methane
Factory calibrated for Hydrogen (For setting to another gas, provide information in the order note)

Features:

  • Sensitive and stable detection
  • Long lifespan of the semiconductor sensor
  • Wall mounting, IP66 protection
  • ATEX zones 2, 22
  • Two analog outputs 4-20mA/0-10V
  • Digital communication ModBus RS485
  • 2 x switching relays

Tip: Get automatically notified of the legal calibration date by the service www.kalibrovat.cz

We respond to your product queries as quickly as possible, usually within 24 hours.