The carbon dioxide detection sensor is used for detecting and providing early warning of dangerous (toxic) concentrations of carbon dioxide. Typical applications include HVAC and air quality control in public spaces, offices, greenhouses, underground garages, or boiler rooms, and other places where toxic levels of carbon dioxide might accumulate. The device uses a calibrated and thermally compensated NDIR optical sensor for accurate detection. This sensor ensures high stability, repeatability, and long lifespan of the detector. In the event of a leak, carbon dioxide can accumulate in enclosed spaces to toxic levels. Therefore, it is necessary to ensure timely warning of a leak using the detector.
Carbon dioxide is heavier than air. The detector should be placed just above the floor, away from corners, recesses, or holes. The recommended coverage area for one detector is 500...1000m², which corresponds to a radius of approximately 12...18m.
The EVIKON E2608-CO2 detector is equipped with a two-stage alarm with outputs to switching relays. It does not have its own light and sound alarm. The E2608 series detectors are an intelligent solution for modern applications with ModBus RS485 communication and two analog outputs 4-20mA/0-10V.
Stock detector settings:
| Measured Gas |
Alarm 1 - Relay 1 |
Alarm 2 - Relay 2 |
| CO2 |
2500ppm CO2 |
5000ppm CO2 |
The sensor can be ordered in the following versions:
1. Wall-mounted (this one)
2. [For duct installation](https://www.bola.cz/detektor-plynu-pro-oxidu-uhlicity-do-vzt-kanalu-evikon-e2608-co2-230-dm)
3. With a cable probe (on request)
Manufactured in a robust design with IP65 protection - ABS plastic, resistant to mechanical damage. Rigid, tough, resistant to low and high temperatures, low water absorption, non-toxic.
The sensor's lifespan is more than 15 years.
Each sensor is factory-calibrated to default values (described in the manual). The law requires recalibration at least once every 12 months. Calibration can only be performed by a person certified by the manufacturer. For recalibration, do not hesitate to contact us!
Features:
- Selective, sensitive, and stable detection
- Long lifespan of the NDIR sensor
- Wall mounting, duct installation, remote probe, IP65 protection
- Two output relays for alarm/ventilation control
- Two analog outputs 4-20mA/0-10V
- Digital communication ModBus RS485
Tip: Get automatically notified of the statutory calibration date with the service [www.kalibrovat.cz](http://www.kalibrovat.cz)