Evikon E2670-R-CO carbon monoxide detector with ModBus RS485 digital communication and two analog outputs 4-20mA/0-10V and two relays. Protection IP66. 24 V AC power supply. Suitable for ATEX zones 2 and 22. More information
Out of stock - can be requested
Would you like to get a price offer? Contact us
Atex | Zone 22, Zone 2 |
Output signal | ModBus RS485, 2x Analog output 4-20mA/0-10V, 2 x switching relays |
Power | 24 VAC |
Type of gas | CO-carbon monoxide |
Weight | 1.00 kg |
Data sheet eng download
Download PDFDeclaration of staircase download
Download PDFThe carbon monoxide detector is used to measure the values of the detected gas in the air and provide early warning of a dangerous (toxic) concentration. Solvent vapors can explode in high concentrations. Therefore, it is necessary to provide early warning of a leak using a detector.
It does not have its own light and sound signaling. The E2670 series detectors are an intelligent solution for modern applications with ModBus RS485 communication and two 4-20mA/0-10V analog outputs . They are also equipped with two switching relays that will switch the connected devices after recording two preset values.
Made in a robust aluminum design with IP66 protection , resistant to mechanical damage. Rigid, tough, resistant to low and high temperatures, harmless to health. Suitable for use in ATEX zones 2 and 22 . More details about ATEX in the declaration of conformity and data sheet.
Each detector is factory-calibrated to default values (described in the manual). According to the needs of the user, the detector can be set to a toxicity range of 0...1000 ppm. The law states that recalibration must be carried out at least once every 6 months. Calibration can only be performed by a person certified by the manufacturer.
The recommended coverage area with one sensor is 80-120 m 2 , 5-6 m radius.
Do not hesitate to contact us for recalibration!
Tip: Let the www.kalibrovat.cz service automatically notify you of the legal calibration date
We respond to your product queries as quickly as possible, usually within 24 hours.
Shopping with us
About us
Personal collection of goods
Opening hours
Contact
Delivery options
Payment options
Copyright © 2025 BOLA spol s.r.o.
Didn't find what you wanted to know?