Evikon E2670-R-LEL propane detector with ModBus RS485 digital communication, two 4–20 mA/0–10 V analogue outputs and two relays. IP66 protection rating. 230 V AC power supply. Suitable for ATEX Zones 2 and 22. More information
Out of stock - can be requested
| Atex | Zone 22, Zone 2 |
| Output signal | ModBus RS485, 2x Analog Output 4-20mA/0-10V, 2 x switching relay |
| Power Supply | 230 VAC |
| Type of gas | CH4-Methane, H2-Hydrogen, C4H10-Butane, C3H8-Propane, C2H2-Acetylene, C3H8-Propane |
| Weight | 1.30 kg |
Data sheet eng download
Download PDFDeclaration of staircase download
Download PDFThe propane detector is used to measure the level of detected gas in the air and to provide early warning of a hazardous (toxic) concentration.
It does not have its own visual or audible alarm. The E2670 series detectors are an intelligent solution for modern applications, featuring ModBus RS485 communication and two analogue outputs 4-20mA/0-10V. They are also equipped with two switching relays, which activate connected devices when two preset values are reached.
Manufactured in a robust aluminium enclosure with IP66 protection, resistant to mechanical damage. Rigid, tough, resistant to both low and high temperatures, and safe for health. Suitable for use in ATEX zones 2 and 22. More detailed information about ATEX can be found in the declaration of conformity and the technical data sheet.
Each detector is factory-calibrated to default values (described in the manual). According to the user's requirements, the detector can be set to a measuring range of 0...100 % LEL. The law stipulates that recalibration must be carried out at least once every 12 months. Calibration may only be performed by a person certified by the manufacturer.
The recommended coverage area for one sensor is 80-120 m2, with a radius of 5-6 m.
Please do not hesitate to contact us for recalibration!
The detector is designed to detect:
Acetylene / Butane / Propane / Hydrogen / Methane
Factory-calibrated for Propane (To set it for a different gas, please include this information in the order note)
Tip: Get automatic reminders of the statutory calibration date via the service www.kalibrovat.cz
We respond to your product queries as quickly as possible, usually within 24 hours.
Shopping with us
About us
Personal collection of goods
Opening hours

Contact
Delivery options
Payment options
Copyright © 2026 BOLA spol s.r.o.
Bola.cz
Nenašli jste to, co jste chtěli vědět?