Questions? +32 460 226 991 (English). EU-wide delivery!

Oxygen detector EVIKON E2638-O2-5Y-B-LCD-R-230

Oxygen detector EVIKON E2638-O2-5Y-B-LCD-R-230

EVIKON
  • Product code: E2638-O2-5Y-B-LCD-R-
  • Warranty: 2 years

Gas detector for oxygen EVIKON E2638-O2-LCD, warning signal: light (flashing display) + sound, LCD display with current measured value, power supply: 90...265 VAC, measurement range: 0...25% O2. More information

  • Availability

    GLS delivery 3-4 working days. DHL express delivery 1-2 working days.

  • In stock 1 pcs  
     
Price without VAT € 507,81
Price with VAT 21 % € 614,45
+

Would you like to get a price offer? Contact us

Parameters and catalogs

Detector type Stationary
Output signal ModBus RS485, 2x Switching relay, 2x Analog output 4-20mA/0-10V
Power 230 VAC
Type of gas CO-carbon monoxide
Weight 0.44 kg

DECLARATION OF CONFORMITY download

Download PDF

Catalog sheet download

Download PDF

CATALOG SHEET ENG download

Download PDF

Gas concentration detection sensor Evikon E2638-O2-5Y-B-LCD-R-230-RP3

The gas concentration detection sensor (gas detector) is used for detection and early warning of a dangerous (explosive or toxic) concentration of the sensed gas. The sensor is suitable for use in underground garages, boiler rooms, kitchens and other closed spaces with the possibility of accumulating dangerous amounts of gas. The detector is equipped with two-stage signaling - visual (LCD display) and sound (85db). Furthermore, two output relays (voltage-free) with a switching contact can be used for remote signaling or ventilation / EM valve control, etc. The sensor is built on the unified PluraSens platform. The platform enables connection of the detector, in addition to switching relays, also with two analog outputs 0-10V / 4-20mA and a ModBus RS485 digital interface.
Made in a robust design with IP65 protection - ABS plastic, resistant to mechanical damage. Rigid, tough, resistant to low and high temperatures, not very absorbent, harmless to health.

The service life of the sensor is more than 10 years.

Default alarm values are set to 19.5% and 18% oxygen. The recommended coverage area with one sensor is 80-120 m 2 , 5-6 m radius.

The law states that recalibration must be carried out at least once every 12 months. Calibration can only be performed by a person certified by the manufacturer.

For more information about calibrations - www.kalibrovat. Czech

The sensor is designed to detect oxygen O2

DETECTOR CALIBRATED FOR OXYGEN.

Properties:

  • Selective, sensitive and stable detection of flammable gases
  • Long sensor life
  • Wall mounting, IP65 protection
  • Visual and audible alarm
  • LCD display
  • Two output relays for alarm / ventilation control
  • ModBus RS485 digital communication
  • Two output analog signals 0-10V/4-20mA

Tip: Let the www.kalibrovat.cz service automatically notify you of the legal calibration date

Tip: The detector can be equipped with a remote cable sensor.

We respond to your product queries as quickly as possible, usually within 24 hours.

Didn't find what you wanted to know?